Back to top
Pole Protection Sleeve
Pole Protection Sleeve

Pole Protection Sleeve

Pole Protection Sleeve Specification

  • Thermal Conductivity
  • 0.42 W/mK
  • Surface Treatment
  • Smooth/Plain
  • Installation Guideline
  • Slide over pole before installation or retro-fit to installed pole
  • Size
  • Custom sizes available
  • Density
  • 0.94 Gram per cubic centimeter(g/cm3)
  • Coating Type
  • Non-coated
  • Layer
  • Single layer
  • Feature
  • UV stabilized, anti-corrosive, weather resistant
  • Product Type
  • Pole Protection Sleeve
  • Material
  • High-Density Polyethylene (HDPE)
  • Rated Voltage
  • Up to 11 kV
  • Tensile Strength
  • 24 MPa
  • Width
  • As per pole diameter (customizable)
  • Thickness
  • 2 mm - 5 mm
  • Application
  • Electric utility poles, telecom poles, street lighting poles
  • Breakdown Voltage
  • 24 kV/mm
  • Heat Conductivity
  • 0.42 W/mK
  • Color
  • Black
  • Max Withstanding Temperature
  • -40C to +80C
  • Recyclability
  • Fully recyclable material
  • Elongation at Break
  • 400%
  • Flame Retardance
  • Yes, self-extinguishing
  • Hardness
  • Shore D 60
  • Operating Life
  • Over 15 years (outdoor exposure)
  • Water Resistance
  • 100% Waterproof
  • Shape
  • Cylindrical sleeve
  • Environmental Compliance
  • RoHS compliant
  • Storage Condition
  • Store in dry, shaded area
  • UV Resistance
  • Excellent, prevents degradation
 
 

About Pole Protection Sleeve

Pole Protection Sleeve

  • voltage-tape
  • voltage-tape

Heat Shrink Pole Protection Sleeve is manufactured from High Quality Cross-linked polyolefin material. It is used on Street lighting poles for Corrosion protection. It provides superior environmental sealing, rugged mechanical protection and high performance electrical insulation.

The combination of Pole Protection Sleeve and Epoxy Paint has been designed to protect poles against decay at the critical ground-line area. It is the Best & Cost-effective Solution for long term maintenance of Poles.

Technical Data

All dimensions are in mm

  • Properties
  • Test Method
  • Typical Value
  • Physical:
  • Tensile Strength
  • ASTM-D-638
  • 11 N/mm2(Min.)
  • Elongation
  • ASTM-D-638
  • 350% (Min.)
  • Water Absorption
  • ASTM-D-570
  • 0.5 (Max)
  • Low Temp. Flexibility
  • ASTM-D-2671
  • -400°C
  • Specific Gravity
  • ASTM-D-792
  • 1.2
  • Longitudinal Change
  • ASTM-D-2671
  • -10%(Max)
  • Thermal:
  • Operating Temp.
  • IEC216
  • -400°C to +1250 C (Outer Wall)
  • Dielectric Lose Angle
  • -
  • No dripping, cracking or flowing
  • @ 2500°C 4 hrs
  • -
  • (Outer Wall)
  • Chemical:
  • Copper Corrosion.
  • ASTM-D-2671 B
  • Good
  • Chemical Resistance
  • ASTM-D-2671
  • Good
  • Electrical :
  • Dielectric Strength
  • ASTM-D-149
  • >15kV / mm
  • Dielectric Constant
  • ASTM-D-150
  • 3.0(Max.)
  • Volume Resistance
  • ASTM-D-257
  • 1014 Ohm / cm (Min)
Features & Benefits:
  • Hot melt adhesive lining provides 100% environmental sealing against weathering, moisture, contamination and adverse environmental conditions according to IP 68.
  • Provides permanent waterproof barrier & environmental seal.
  • High resistance to UV rays, chemicals, corrosion, fungus, etc.
  • Stocking only a few sizes will fit most repair needs.
  • Sleeve can be cut to size in field to suit application.
  • Custom dimensions available on request.
  • Service life of Pole Protection Sleeve is more than 30 years.
  • Easy installation on concrete, steel or composite poles.
  • Use of Pole Protection Sleeves typically adds some nominal percentage to the total cost of New Pole replacement.
  • Standard Heat Shrinkable Sleeve (GMW) in tubular form is recommended to use on fresh Poles before installation for corrosion protection.
Pole Protection Sleeve has many recommended uses:
  • Relocated or reused poles
  • New poles, especially those to be set in pavement
  • Poles set in locations vulnerable to decay
  • High value installations
  • Standing poles that have the ground-line disturbed for underground cable installations or grade change
  • Poles stored for six months or more
SELECTION CHART

All dimensions are in mm

  • Gala Code
  • Pole OD (mm)
  • Length (mm)
  • Overlap Length (mm)
  • GMRS-502
  • 70 - 122
  • 300/400
  • 50 (min)
  • GMRS-628
  • 70 - 145
  • 300/400
  • 75 (min)
  • GMRS-785
  • 140 - 190
  • 300/400
  • 75 (min)
  • GMRS-1005
  • 150 - 250
  • 300/400
  • 75(min)
  • GMRS-1178
  • 160 - 290
  • 300/400
  • 75(min).
  • GMRS-1335
  • 175 - 360
  • 300/400
  • 75(min)
SELECTION CHART

All dimensions are in mm

  • Gala Code
  • D (Min.)(mm)
  • d (Max.)(mm)
  • T (±10%)(mm)
  • Length(mm)
  • GMW 180/55
  • 180
  • 55
  • 3.3
  • 400/500
  • GMW 200/60
  • 200
  • 60
  • 3.5
  • 400 / 500
  • GMW 250/70
  • 250
  • 70
  • 3.5
  • 400 / 500
  • GMW 320/90
  • 320
  • 90
  • 3.5
  • 400 / 500
  • GMW 375/110
  • 375
  • 110
  • 3.5
  • 400 / 500
  • GMW 425/120
  • 425
  • 120
  • 3.5
  • 400 / 500


Outstanding Performance in Extreme Conditions

Engineered for harsh environments, this pole protection sleeve offers maximum defense against UV rays, corrosion, moisture, and temperature swings from -40C to +80C. Its HDPE construction is not only weather-resistant but also flame retardant and waterproof, making it dependable across diverse climates and locations.


Sustainable and Compliant Design

The sleeve is manufactured from fully recyclable materials and adheres to RoHS environmental standards. This ensures not only pole longevity but also a reduced ecological impact compared to conventional materials, aligning with modern sustainability goals.


Reliable Electrical and Mechanical Protection

With a rated voltage of up to 11 kV and a breakdown voltage of 24 kV/mm, this protection sleeve ensures safety for electric and telecom installations. Its Shore D 60 hardness, smooth surface, and customizable sizing make it suitable for a variety of pole applications, while keeping maintenance needs minimal.

FAQs of Pole Protection Sleeve:


Q: How do I install the Pole Protection Sleeve on a pole?

A: Installation is simple and can be completed by sliding the cylindrical sleeve over the pole before its installation or retrofitting it onto an already installed pole. The sizing can be customized according to pole diameters, ensuring a secure fit.

Q: What types of poles is the sleeve suitable for?

A: This protection sleeve is designed for electric utility, telecom, and street lighting poles, offering broad applicability in infrastructure projects across industries.

Q: When should the Pole Protection Sleeve be used?

A: It is ideal for environments where poles are exposed to sunlight, moisture, and fluctuating temperatures, especially in outdoor settings requiring long-term reliability and compliance with safety standards.

Q: Where can the Pole Protection Sleeve be applied?

A: The sleeve is commonly used in outdoor locations such as streets, highways, power distribution sites, and telecom installations where pole degradation due to environmental factors is a concern.

Q: What are the benefits of using a UV-resistant and flame-retardant sleeve?

A: The sleeves UV resistance prevents degradation from sunlight, while its flame-retardant properties contribute to higher safety by self-extinguishing flames, reducing maintenance costs and extending the operational life of the pole.

Q: Is the material environmentally safe and recyclable?

A: Yes, the pole sleeve is made from HDPE, is fully recyclable, and meets RoHS environmental compliance standards, making it a sustainable choice for infrastructure projects.

Q: How long does the Pole Protection Sleeve last in outdoor environments?

A: Designed for durability, the sleeve offers an operating life of over 15 years in outdoor exposure, maintaining its physical and electrical properties throughout its lifespan.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pole Protection Products Category

Heat Shrinkable Pole Cap

Heat Shrinkable Pole Cap

Width : Custom as per pole diameter

Installation Guideline : Clean pole top, fit cap, uniformly apply heat for full shrinkage and seal

Max Withstanding Temperature : 110C continuous

Surface Treatment : Smooth, antitracking finish

Color : Red/Black

Thickness : 2.5 mm

Vinyl Cap

Vinyl Cap

Width : Varies as per size (standard 10 mm to 50 mm)

Installation Guideline : Simply push onto the application; No adhesives required

Max Withstanding Temperature : 85C

Surface Treatment : Smooth Finish

Color : Red, Yellow, Blue, Green, Black, Custom available

Thickness : 0.5 mm to 2 mm

PVC Cap

PVC Cap

Width : Varies depending on size

Installation Guideline : Slide over cable end and heat for proper fit

Max Withstanding Temperature : Up to 105C

Surface Treatment : Smooth surface finish

Color : Black Red Blue

Thickness : Varies depending on size

Dock Pile Cap

Dock Pile Cap

Width : Custom as per pile diameter

Installation Guideline : Predrilled and fixed with SS screws or expansion anchors

Max Withstanding Temperature : 40C to +80C

Surface Treatment : UV Resistant Coating

Color : Black, Grey, or Custom

Thickness : 10 mm to 40 mm