End Cap with Cable Pulling Eye Specification

  • Conductor Shape
  • Round
  • Dielectiric Strength
  • 20kV/mm
  • Diameter
  • 80mm
  • Usage & Applications
  • Pulling and terminating power cables in industrial, commercial, or utility installations
  • Number of Conductor
  • As per cable used
  • Core Material
  • Copper/Aluminum
  • Weight
  • 300g
  • Conductor Type
  • Stranded or solid
  • Install Type
  • Manual
  • Cable Type
  • Power cable
  • Rated Temperature
  • -40C to +90C
  • Core Number
  • Single/Multiple (application based)
  • Insulation
  • High-grade insulation
  • Features
  • Weatherproof, corrosion resistant, high durability, easy cable pulling eye attachment
  • Locking Type
  • Pulling eye with secure attachment
  • Armored Material
  • Steel
  • Tensile Strength
  • 25 N/mm
  • Operating Temperature
  • -40C to +90C
  • Product Type
  • End Cap with Cable Pulling Eye
  • Length
  • Standard size as per cable termination requirement
  • Voltage
  • Suitable for cables up to 36kV
  • Insulation Material
  • EPDM Rubber
  • Application
  • Cable termination and sealing, underground cable jointing
  • Conductor Material
  • Copper (dependent on cable specification)
  • Jacket Material
  • High-strength plastic
  • Storage Temperature
  • -20C to +60C
  • Connector Color
  • Silver
  • Shield Material
  • Galvanized steel
  • Jacket Color
  • Black
  • Dimension (L*W*H)
  • 180mm x 80mm x 80mm
  • Material
  • EPDM Rubber with metallic eye
  • Color
  • Black
  • Size
  • Customizable as per cable requirements
  • Standards Compliance
  • IEC, IS and EN standards
  • Surface Finish
  • Smooth, burr-free edges
  • Pulling Eye Material
  • Galvanized Steel (rust-resistant)
  • Lead Time for Delivery
  • 24 weeks from order confirmation
  • RoHS Compliance
  • Yes
  • Corrosion Protection
  • Galvanized/Powder-coated steel eyelet
  • UV Resistance
  • Yes (suitable for outdoor installations)
  • Resistance to Chemicals
  • High suitable for harsh environments
  • Minimum Order Quantity
  • Subject to manufacturer policy
  • Environmental Suitability
  • Indoor and Outdoor
  • Flame Retardancy
  • Meets IEC 60332-1
  • Ingress Protection
  • IP68 (when properly installed)
  • Installation Accessories
  • Available upon request (clamps, adhesive)
 
 

About End Cap with Cable Pulling Eye

These Heat Shrink End Caps with Cable Pulling Eye for Telephone and Power cable are the ultimate solution in cable pulling eyes. These caps with pulling eye form a connection as strong as the cable itself. The entire cable, jacket and conductor, is used which reduces the risk of cable deformation during pulling. When properly installed, Heat Shrink End Caps with Cable Pulling Eye are virtually impossible to pull off and also seal the cable against both water and moisture intrusion. Typically factory installed, the pulling eyes can also be field installed with a propane (preferred) or butane gas torch.

Features / Benefits:
Technical Specification
  • Properties
  • Value
  • Standard
  • Physical
  •  
  •  
  • Tensile Strength
  • 12 N/mm2 (Min.)
  • ASTM D638
  • Ultimate Elongation
  • 350 % (min)
  • ASTM D638
  • Density
  • 1.05 0.2 gm/cm3
  • ASTM D792
  • Hardness
  • 45 10 Shore D
  • ASTM D2240
  • Water absorption
  • 0.2 % (max.)
  • ASTM D570
  • Thermal
  •  
  •  
  • Accelerated ageing
  • (120 C for 500 hrs)
  • ASTM D2671
  • Tensile Strength
  • 11 N/mm 2 (Mpa) (min.)
  • ASTM D638
  • Ultimate Elongation
  • 300 % (min.)
  • ASTM D638
  • Low Temperature Flexibility (-40 C for 4 hrs.)
  • No Cracking
  • ASTM D2671
  • Heat Shock (250 C for 30 min.)
  • No cracking or flowing
  • ESI 09-11
  • Shrink Temperature
  • 125 C
  • IEC 216
  • Continuous Temperature Limit
  • -40 to +100 C
  • IEC 216
  • Electrical
  •  
  •  
  • Dielectric Strength
  • 12 KV/mm.(min)
  • ASTM D149
  • Volume Resistivity
  • 1 x 1014 Ohm.cm (min)
  • ASTM D257
  • Dielectric constant
  • 5 (max.)
  • ASTM D150
  • Min. Pulling Force 13 N/mm2
  • Dual application: 100% sealing & pulling cable
  • Most economical compare to other pulling eyes
  • No special tools or crimpers required
  • Reduces the risk of cable deformation during pulling
  • Single inventory
Selection Chart

All dimensions are in mm

  • Code No.
  • Ds
  • Df
  • Ls
  • Tf
  • Pulling
  • Cable
  •  
  • (Min.)
  • (Max.)
  • (Min.)
  • (10%)
  • Strength (Min.)
  • Range
  • GEC 301L-PE
  • 55
  • 25
  • 170
  • 3.5
  • 150 Kgs.
  • 28 - 38
  • GEC 401L-PE
  • 75
  • 35
  • 180
  • 4.0
  • 250 Kgs.
  • 38 - 52
  • GEC 501L-PE
  • 100
  • 45
  • 200
  • 4.0
  • 300 Kgs.
  • 50 - 70
  • GEC 601L-PE
  • 130
  • 65
  • 300
  • 4.6
  • 400 Kgs.
  • 65 - 91
  • GEC 701L-PE
  • 160
  • 65
  • 300
  • 4.5
  • 450 Kgs.
  • 80 - 112


Engineered for Extreme Durability

This end cap is crafted with high-grade EPDM rubber and a galvanized steel pulling eye, ensuring long-term resistance against harsh chemicals, corrosion, and UV exposure. Its smooth, burr-free edges and robust construction make it ideal for both indoor and outdoor cable terminations, pulling applications, and underground installations.


Superior Protection & Standards Compliance

Rated to IP68 when properly installed, the end cap provides exceptional protection against water and dust ingress. It conforms to IEC, IS, and EN standards, with flame-retardant, weatherproof properties and RoHS compliance. This ensures safe and reliable cable terminations even in the most challenging industrial settings.

FAQs of End Cap with Cable Pulling Eye:


Q: How is the End Cap with Cable Pulling Eye installed?

A: The cap is manually installed at the cable end, with the pulling eye securely attached to enable smooth cable termination and pulling. Clamps, adhesive, and other installation accessories can be supplied on request for added convenience.

Q: What are the main benefits of using this end cap in industrial or outdoor applications?

A: It offers high chemical resistance, IP68 ingress protection, flame retardancy, UV resistance, and corrosion prevention. These attributes ensure reliable sealing, enhanced cable lifespan, and safe operation even in harsh environments.

Q: When should I use this end cap?

A: This product is ideal for cable terminations in underground, industrial, utility, or outdoor installationsespecially where exposure to chemicals, moisture, or extreme temperatures is expected.

Q: Where can this end cap be used?

A: It is suitable for both indoor and outdoor environments, including industrial facilities, commercial buildings, utility sites, and specifically for power cables up to 36kV.

Q: What is the process for obtaining this end cap?

A: After confirming your order and specifying cable requirements, the standard lead time for delivery is between 24 weeks. Minimum order quantity may apply as per manufacturer policy.

Q: What standards does the product comply with?

A: The end cap meets IEC, IS, and EN standards for electrical safety, flame retardancy (IEC 60332-1), and RoHS environmental directives.

Q: Can the size and configuration be customized?

A: Yes, customization is available to match your cables termination requirements, ensuring optimal fit and performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cable Sealing & Repair Products Category

Cable Repair Products

Cable Repair Products

Jacket Material : Other, Polyolefin, PVC

Dimension (L*W*H) : Variable; typically 1000mm x 20mm x 2mm (custom sizes available)

Usage & Applications : Restoring insulation integrity, preventing moisture ingress, covering cable joints

Length : Varies as per requirement (standard: 1 meter, 2 meter, 5 meter, or custom)

Storage Temperature : 10C to +50C

Product Type : Cable Repair Sleeve/Heat Shrink Tubing

Wrap Around Sleeve

Wrap Around Sleeve

Jacket Material : Other, Polyolefin

Dimension (L*W*H) : Custom sizes available

Usage & Applications : Repairing of cable jackets, Insulation restoration, Environmental protection

Length : Customizable as per requirement

Storage Temperature : 40C to +60C

Product Type : Wrap Around Sleeve

Temper Proof End Seal

Temper Proof End Seal

Jacket Material : Other, PVC/Polymer

Dimension (L*W*H) : Custom / As required

Usage & Applications : Cable termination, End sealing, Safety

Length : Standard and customizable as per requirement

Storage Temperature : 20C to 70C

Product Type : Temper Proof End Seal

Cable Repair Sleeve

Cable Repair Sleeve

Jacket Material : Other, Crosslinked Polyolefin

Dimension (L*W*H) : Depends on cable size; standard: 500mm x 40mm x 2mm

Usage & Applications : Outdoor/indoor cable repair, electrical insulation, waterproof cable jointing

Length : Customizable as per application (typically 0.5 to 1.5 meter)

Storage Temperature : 20C to +50C

Product Type : Cable Repair Sleeve