About End Cap with Cable Pulling Eye
These Heat Shrink End Caps with Cable Pulling Eye for Telephone and Power cable are the ultimate solution in cable pulling eyes. These caps with pulling eye form a connection as strong as the cable itself. The entire cable, jacket and conductor, is used which reduces the risk of cable deformation during pulling. When properly installed, Heat Shrink End Caps with Cable Pulling Eye are virtually impossible to pull off and also seal the cable against both water and moisture intrusion. Typically factory installed, the pulling eyes can also be field installed with a propane (preferred) or butane gas torch.
Features / Benefits:
Technical Specification
- Tensile Strength
- 12 N/mm2 (Min.)
- ASTM D638
- Ultimate Elongation
- 350 % (min)
- ASTM D638
- Density
- 1.05 0.2 gm/cm3
- ASTM D792
- Hardness
- 45 10 Shore D
- ASTM D2240
- Water absorption
- 0.2 % (max.)
- ASTM D570
- Accelerated ageing
- (120 C for 500 hrs)
- ASTM D2671
- Tensile Strength
- 11 N/mm 2 (Mpa) (min.)
- ASTM D638
- Ultimate Elongation
- 300 % (min.)
- ASTM D638
- Low Temperature Flexibility (-40 C for 4 hrs.)
- No Cracking
- ASTM D2671
- Heat Shock (250 C for 30 min.)
- No cracking or flowing
- ESI 09-11
- Shrink Temperature
- 125 C
- IEC 216
- Continuous Temperature Limit
- -40 to +100 C
- IEC 216
- Dielectric Strength
- 12 KV/mm.(min)
- ASTM D149
- Volume Resistivity
- 1 x 1014 Ohm.cm (min)
- ASTM D257
- Dielectric constant
- 5 (max.)
- ASTM D150
- Min. Pulling Force 13 N/mm2
- Dual application: 100% sealing & pulling cable
- Most economical compare to other pulling eyes
- No special tools or crimpers required
- Reduces the risk of cable deformation during pulling
- Single inventory
Selection Chart
All dimensions are in mm
- Code No.
- Ds
- Df
- Ls
- Tf
- Pulling
- Cable
-
- (Min.)
- (Max.)
- (Min.)
- (10%)
- Strength (Min.)
- Range
- GEC 301L-PE
- 55
- 25
- 170
- 3.5
- 150 Kgs.
- 28 - 38
- GEC 401L-PE
- 75
- 35
- 180
- 4.0
- 250 Kgs.
- 38 - 52
- GEC 501L-PE
- 100
- 45
- 200
- 4.0
- 300 Kgs.
- 50 - 70
- GEC 601L-PE
- 130
- 65
- 300
- 4.6
- 400 Kgs.
- 65 - 91
- GEC 701L-PE
- 160
- 65
- 300
- 4.5
- 450 Kgs.
- 80 - 112
Engineered for Extreme DurabilityThis end cap is crafted with high-grade EPDM rubber and a galvanized steel pulling eye, ensuring long-term resistance against harsh chemicals, corrosion, and UV exposure. Its smooth, burr-free edges and robust construction make it ideal for both indoor and outdoor cable terminations, pulling applications, and underground installations.
Superior Protection & Standards ComplianceRated to IP68 when properly installed, the end cap provides exceptional protection against water and dust ingress. It conforms to IEC, IS, and EN standards, with flame-retardant, weatherproof properties and RoHS compliance. This ensures safe and reliable cable terminations even in the most challenging industrial settings.
FAQs of End Cap with Cable Pulling Eye:
Q: How is the End Cap with Cable Pulling Eye installed?
A: The cap is manually installed at the cable end, with the pulling eye securely attached to enable smooth cable termination and pulling. Clamps, adhesive, and other installation accessories can be supplied on request for added convenience.
Q: What are the main benefits of using this end cap in industrial or outdoor applications?
A: It offers high chemical resistance, IP68 ingress protection, flame retardancy, UV resistance, and corrosion prevention. These attributes ensure reliable sealing, enhanced cable lifespan, and safe operation even in harsh environments.
Q: When should I use this end cap?
A: This product is ideal for cable terminations in underground, industrial, utility, or outdoor installationsespecially where exposure to chemicals, moisture, or extreme temperatures is expected.
Q: Where can this end cap be used?
A: It is suitable for both indoor and outdoor environments, including industrial facilities, commercial buildings, utility sites, and specifically for power cables up to 36kV.
Q: What is the process for obtaining this end cap?
A: After confirming your order and specifying cable requirements, the standard lead time for delivery is between 24 weeks. Minimum order quantity may apply as per manufacturer policy.
Q: What standards does the product comply with?
A: The end cap meets IEC, IS, and EN standards for electrical safety, flame retardancy (IEC 60332-1), and RoHS environmental directives.
Q: Can the size and configuration be customized?
A: Yes, customization is available to match your cables termination requirements, ensuring optimal fit and performance.